sales@hancox.co.uk    +44 (0) 1564 824343
 
 

KOHLER® MAINTENANCE

Command C6 and Command 11-15hp Single Cylinders
FREQUENCY   MAINTENANCE REQUIRED
Daily or before starting engine   Fill fuel tank
Check oil level
Check air cleaner for dirty*, loose or damaged parts
Check air intake and cooling areas, clean as necessary*
     
Every 25 hours    Service Pre cleaner element*
(clean in petrol or soapy water then re-oil with a drop of oil squeezed through the foam)
     
Every 100 hours   Replace the air cleaner element*
Change the oil
Check spark plug condition and gap
Remove cooling shrouds and clean cooling areas*
     
Every 200 hours   Change oil filter on the Command 11 - 15hp singles
*Perform this task more often under adverse dusty or dirty working conditions
Command V Twins and OHC Engines
FREQUENCY   MAINTENANCE REQUIRED
Daily or before starting engine   Fill fuel tank
Check oil level
Check air cleaner for dirty*, loose or damaged parts
Check air intake and cooling areas, clean as necessary*
     
Every 25 hours   Service Pre cleaner element*
(clean in petrol or soapy water then re-oil with a drop of oil squeezed through the foam)
     
Every 100 hours   Replace the air cleaner element*
Change the oil
Remove cooling shrouds and clean cooling areas*
     
Every 200 hours   Change the oil filter
Check spark plug condition and gap on the OHC engines
*Perform this task more often under adverse dusty or dirty working conditions
Command CS Engines
FREQUENCY   MAINTENANCE REQUIRED
Daily or before starting engine   Fill fuel tank
Check oil level
Check air cleaner for dirty*, loose or damaged parts
Check air intake and cooling areas, clean as necessary*
     
Every 25 hours   Service Pre cleaner element*
(clean in petrol or soapy water then re-oil with a drop of oil squeezed through the foam)
     
Every 100 hours   Replace the air cleaner element*
Change the oil
Remove cooling shrouds and clean cooling areas*
*Perform this task more often under adverse dusty or dirty working conditions
Magnum Singles and Twins
FREQUENCY   MAINTENANCE REQUIRED
Daily or before starting engine   Fill fuel tank
Check oil level
Check air cleaner for dirty*, loose or damaged parts
Check air intake and cooling areas, clean as necessary*
     
Every 25 hours   Service Pre cleaner element*
(clean in petrol or soapy water then re-oil with a drop of oil squeezed through the foam)
 
Every 100 hours   Replace the air cleaner element*
Change the oil
Remove cooling shrouds and clean cooling areas*
Check spark plug contition and gap
*Perform this task more often under adverse dusty or dirty working conditions